A tensile test was conducted on a specimen with a diameter of 0.5 inch. A strain gage was bonded to the specimen so that the strain could be obtained directly. The fol- lowing data were obtained:
Load (Ib) Strain (micro in /in.) 2,000 47
2,500 220
3,000 500
3,500 950
4,000 1,111
4,500 1,200
5,000 1,702

A. Create a table of stress and strain values.