Answer:
the required mass flow rate is 49484.37 kg/s
Explanation:
Given the data in the question;
we first determine the relation for mass flow rate of water that passes through the turbine;
so the relation for net work on the turbine due to the change in potential energy considering 100% efficiency is;
[tex]W_{net}[/tex] = m ( Î P.E )
so we substitute (gh) for ( Î P.E );
[tex]W_{net}[/tex] = m (gh)
m = [tex]W_{net}[/tex] / gh
so we substitute our given values into the equation
m = 100 MW / ( 9.81 m/s²) à 206 m
m = ( 100 MW Ă 10âśW/MW) / ( 9.81 m/s²) Ă 206 m
m = 10 à 10⡠/ 2020.86
m = 49484.37 kg/s
Therefore, the required mass flow rate is 49484.37 kg/s